Lab director requirements under CLIA

What a person needs to serve as laboratory director depends on the most complex testing the lab performs and on the state. This page sets out every federal pathway, with the official text.

Reviewed November 27, 2026 by the Sound Lab Consultants laboratory compliance team

Short answer

For moderate complexity, a lab director must be a board-certified pathologist, or an MD/DO/DPM with 1 year directing or supervising nonwaived testing and 20 CE hours, or meet a doctoral, master's or bachelor's pathway with experience and 20 CE hours. High complexity requires a pathologist, an MD/DO/DPM with 2 years of high complexity experience and 20 CE hours, or a board-certified doctoral scientist with 2 years' experience and 20 CE hours.

Step 1: the state license

Both director standards start with the same rule: the director must possess a current state license as a laboratory director if the state requires one (42 CFR § 493.1405(a), 42 CFR § 493.1443(a)). Check your state on lab directors by state.

Moderate complexity lab director

PathwayEducationExperienceCE
1MD or DO licensed in the state, certified in anatomic and/or clinical pathology (ABP or AOBP)None beyond certification-
2MD, DO or DPM licensed in the stateAt least 1 year directing or supervising nonwaived testing20 CE hours on director responsibilities
3Earned doctoral degree in a chemical, biological, clinical or medical laboratory science or MT (or other doctorate with 16 semester hours of qualifying doctoral coursework or a qualifying thesis)Board certified by an HHS-approved board and at least 1 year directing or supervising nonwaived testing20 CE hours
4Master's in a chemical, biological, clinical or medical lab science or MT (or bachelor's equivalency plus 16 graduate semester hours)1 year of nonwaived training/experience and 1 year of nonwaived supervisory experience20 CE hours
5Bachelor's in a chemical, biological, clinical or medical lab science or MT (or 120 semester hours with the required science mix)2 years of nonwaived training/experience and 2 years of nonwaived supervisory experience20 CE hours

Source: 42 CFR § 493.1405(b).

High complexity lab director

PathwayEducationExperienceCE
1MD or DO licensed in the state, certified in anatomic and/or clinical pathology (ABP or AOBP)None beyond certification-
2MD, DO or DPM licensed in the stateAt least 2 years directing or supervising high complexity testing20 CE hours
3Earned doctoral degree in a chemical, biological, clinical or medical lab science or MT (or qualifying other doctorate)Certified by an HHS-approved board, plus 2 years of lab training/experience and 2 years directing or supervising high complexity testing20 CE hours

Source: 42 CFR § 493.1443(b). Oral pathology labs need certification by the American Board of Oral Pathology, ABP or AOBP.

PPM lab director

A lab with a certificate for provider-performed microscopy needs a director who is a physician, a dentist, or a midlevel practitioner (nurse practitioner, nurse midwife, physician assistant and others defined in 42 CFR § 493.2) authorized by the state to practice independently (42 CFR § 493.1357).

Waived labs

CLIA does not set director qualifications for a certificate of waiver. The lab must follow manufacturers' instructions and the certificate of waiver rules (42 CFR § 493.15(e)).

The 20 CE hours rule and grandfathering

The CMS final rule published December 28, 2023 (88 FR 90039) added the requirement for 20 continuing education credit hours in laboratory practice covering the director responsibilities in 42 CFR § 493.1407 or 42 CFR § 493.1445 for most non-pathologist pathways, and removed physical science degrees as a qualifying route. Anyone qualified and serving as a director as of December 28, 2024, who has served continuously since, remains qualified (42 CFR § 493.1405(b)(6), 42 CFR § 493.1443(b)(4)).

Changing labs can end continuous service. If a grandfathered director stops serving, they must meet the current pathways for any new position.

How we verify a director

  1. Primary-source license check in the lab's state, including any state laboratory director license.
  2. Board certification or degree verification and transcripts where coursework matters.
  3. Experience letters showing nonwaived or high complexity supervision with dates.
  4. CE certificates covering director responsibilities.
  5. Count of current directorships to stay within the five-lab limit.

Regulations behind this page

Every requirement on this page comes from the CLIA regulations, Title 42 Code of Federal Regulations Part 493. Open any section for the official text.

RegulationWhat it covers
42 CFR § 493.1405Standard; Laboratory director qualificationsModerate complexity laboratory director qualifications
42 CFR § 493.1443Standard; Laboratory director qualificationsHigh complexity laboratory director qualifications
42 CFR § 493.1357Standard; laboratory director qualificationsPPM laboratory director qualifications
42 CFR § 493.2DefinitionsDefinitions, including physician and midlevel practitioner
42 CFR § 493.15Laboratories performing waived testsWaived tests and what a waived lab must do
Full text: 42 CFR § 493.1405 Standard; Laboratory director qualifications

§ 493.1405 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and the performance of moderate complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R of this part. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have had laboratory training or experience consisting of: (A) At least 1 year directing or supervising nonwaived laboratory testing; and (B) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; and (A) Be certified and continue to be certified by a board approved by HHS; and (B) Have had at least 1 year of experience directing or supervising nonwaived laboratory testing; or (4)(i)(A) Have earned a master's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B)( 1 ) Meet bachelor's degree equivalency; and (2) Have at least 16 semester hours of additional graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science; or (C)( 1 ) Meet bachelor's degree equivalency; and ( 2 ) Have at least 16 semester hours in a combination of graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science and an approved thesis or research project related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 1 year of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 1 year of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407; or (5)(i)(A) Have earned a bachelor's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) At least 120 semester hours, or equivalent, from an accredited institution that, at a minimum, includes either— ( 1 ) Forty-eight (48) semester hours of medical laboratory science or medical laboratory technology courses; or ( 2 ) Forty-eight (48) semester hours of science courses that include— ( i ) Twelve (12) semester hours of chemistry, which must include general chemistry and biochemistry or organic chemistry; ( ii ) Twelve (12) semester hours of biology, which must include general biology and molecular biology, cell biology or genetics; and ( iii ) Twenty-four (24) semester hours of chemistry, biology, or medical laboratory science or medical laboratory technology in any combination; and (ii) Have at least 2 years of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 2 years of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407. (6) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of moderate complexity testing under this section if they were qualified and serving as a laboratory director of moderate complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5233, Jan. 19, 1993; 88 FR 90039, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1443 Standard; Laboratory director qualifications

§ 493.1443 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, a doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have at least 2 years of experience directing or supervising high complexity testing; and (iii) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Be certified and continue to be certified by a board approved by HHS; and (iii) Have at least 2 years of: (A) Laboratory training or experience, or both: and (B) Laboratory experience directing or supervising high complexity testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (4) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of high complexity testing under this section if they were qualified and serving as a laboratory director of high complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. (5) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, or the American Osteopathic Board of Pathology. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5234, Jan. 19, 1993; 59 FR 62609, Dec. 6, 1994; 62 FR 25858, May 12, 1997; 63 FR 55034, Oct. 14, 1998; 65 FR 82944, Dec. 29, 2000; 68 FR 3713, Jan. 24, 2003; 88 FR 90041, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1357 Standard; laboratory director qualifications

§ 493.1357 Standard; laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and the performance of PPM procedures as specified in § 493.19(c) and must be eligible to be an operator of a laboratory within the requirements of subpart R of this part. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if the licensing is required. (b) The laboratory director must meet one of the following requirements: (1) Be a physician, as defined in § 493.2. (2) Be a midlevel practitioner, as defined in § 493.2, authorized by a State to practice independently in the State in which the laboratory is located. (3) Be a dentist, as defined in § 493.2.

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.2 Definitions

§ 493.2 Definitions. As used in this part, unless the context indicates otherwise— Acceptance limit means the symmetrical tolerance (plus and minus) around the target value. Accredited institution means a school or program which— (a) Admits as regular student only persons having a certificate of graduation from a school providing secondary education, or the recognized equivalent of such certificate; (b) Is legally authorized within the State to provide a program of education beyond secondary education; (c) Provides an educational program for which it awards a bachelor's degree or provides not less than a 2-year program which is acceptable toward such a degree, or provides an educational program for which it awards a master's or doctoral degree; (d) Is accredited by a nationally recognized accrediting agency or association. This definition includes any foreign institution of higher education that HHS or its designee determines meets substantially equivalent requirements. Accredited laboratory means a laboratory that has voluntarily applied for and been accredited by a private, nonprofit accreditation organization approved by CMS in accordance with this part; Adverse action means the imposition of a principal or alternative sanction by CMS. ALJ stands for Administrative Law Judge. Alternative sanctions means sanctions that may be imposed in lieu of or in addition to principal sanctions. The term is synonymous with “intermediate sanctions” as used in section 1846 of the Act. Analyte means a substance or constituent for which the laboratory conducts testing. Approved accreditation organization for laboratories means a private, nonprofit accreditation organization that has formally applied for and received CMS's approval based on the organization's compliance with this part. Approved State laboratory program means a licensure or other regulatory program for laboratories in a State, the requirements of which are imposed under State law, and the State laboratory program has received CMS approval based on the State's compliance with this part. Authorized person means an individual authorized under State law to order tests or receive test results, or both. Calibration means a process of testing and adjusting an instrument or test system to establish a correlation between the measurement response and the concentration or amount of the substance that is being measured by the test procedure. Calibration verification means the assaying of materials of known concentration in the same manner as patient samples to substantiate the instrument or test system's calibration throughout the reportable range for patient test results. Challenge means, for quantitative tests, an assessment of the amount of substance or analyte present or measured in a sample. For qualitative tests, a challenge means the determination of the presence or the absence of an analyte, organism, or substance in a sample. CLIA means the Clinical Laboratory Improvement Amendments of 1988. CLIA certificate means any of the following types of certificates issued by CMS or its agent: (1) Certificate of compliance means a certificate issued to a laboratory after an inspection that finds the laboratory to be in compliance with all applicable condition level requirements, or reissued before the expiration date, pending an appeal, in accordance with § 493.49, when an inspection has found the laboratory to be out of compliance with one or more condition level requirements. (2) Certificate for provider-performed microscopy (PPM) procedures means a certificate issued or reissued before the expiration date, pending an appeal, in accordance with § 493.47, to a laboratory in which a physician, midlevel practitioner or dentist performs no tests other than PPM procedures and, if desired, waived tests listed in § 493.15(c). (3) Certificate of accreditation means a certificate issued on the basis of the laboratory's accreditation by an accreditation organization approved by CMS (indicating that the laboratory is deemed to meet applicable CLIA requirements) or reissued before the expiration date, pending an appeal, in accordance with § 493.61, when a validation or complaint survey has found the laboratory to be noncompliant with one or more CLIA conditions. (4) Certificate of registration or registration certificate means a certificate issued or reissued before the expiration date, pending an appeal, in accordance with § 493.45, that enables the entity to conduct moderate or high complexity laboratory testing or both until the entity is determined to be in compliance through a survey by CMS or its agent; or in accordance with § 493.57 to an entity that is accredited by an approved accreditation organization. (5) Certificate of waiver means a certificate issued or reissued before the expiration date, pending an appeal, in accordance with § 493.37, to a laboratory to perform only the waived tests listed at § 493.15(c). CLIA-exempt laboratory means a laboratory that has been licensed or approved by a State where CMS has determined that the State has enacted laws relating to laboratory requirements that are equal to or more stringent than CLIA requirements and the State licensure program has been approved by CMS in accordance with subpart E of this part. CMS agent means an entity with which CMS arranges to inspect laboratories and assess laboratory activities against CLIA requirements and may be a State survey agency, a private, nonprofit organization other than an approved accreditation organization, a component of HHS, or any other governmental component CMS approves for this purpose. In those instances where all of the laboratories in a State are exempt from CLIA requirements, based on the approval of a State's exemption request, the State survey agency is not the CMS agent. Condition level deficiency means noncompliance with one or more condition level requirements. Condition level requirements means any of the requirements identified as “conditions” in § 493.41 and subparts G through Q of this part. Confirmatory testing means testing performed by a second analytical procedure that could be used to substantiate or bring into question the result of an initial laboratory test. Continuing education (CE) credit hours means either continuing medical education (CME) or continuing education units (CEUs). The CE credit hours must cover the applicable laboratory director responsibilities and be obtained prior to qualifying as a laboratory director. Credible allegation of compliance means a statement or documentation that— (1) Is made by a representative of a laboratory that has a history of having maintained a commitment to compliance and of taking corrective action when required; (2) Is realistic in terms of its being possible to accomplish the required corrective action between the date of the exit conference and the date of the allegation; and (3) Indicates that the problem has been resolved. Dentist means a doctor of dental medicine or doctor of dental surgery licensed by the State to practice dentistry within the State in which the laboratory is located. Distributive testing means laboratory testing performed on the same specimen, or an aliquot of it, that requires sharing it between two or more laboratories to obtain all data required to complete an interpretation or calculation necessary to provide a final reportable result for the originally ordered test. When such testing occurs at multiple locations with different CLIA certificates, it is considered distributive testing. Doctoral degree means an earned post-baccalaureate degree with at least 3 years of graduate level study that includes research related to clinical laboratory testing or advanced study in clinical laboratory science, medical laboratory science, or medical technology. For purposes of this part, doctoral degrees do not include doctors of medicine (MD), doctors of osteopathy (DO), doctors of podiatric medicine (DPM), doctors of veterinary medicine (DVM) degrees, or honorary degrees. Equivalency means that an accreditation organization's or a State laboratory program's requirements, taken as a whole, are equal to or more stringent than the CLIA requirements established by CMS, taken as whole. It is acceptable for an accreditation organization's or State laboratory program's requirements to be organized differently or otherwise vary from the CLIA requirements, as long as (1) All of the requirements taken as a whole would provide at least the same protection as the CLIA requirements taken as a whole; and (2) A finding of noncompliance with respect to CLIA requirements taken as a whole would be matched by a finding of noncompliance with the accreditation or State requirements taken as a whole. Experience directing or supervising means that the director or supervisory experience must be obtained in a facility that meets the definition of a laboratory under this section and is not excepted under § 493.3(b). FDA-cleared or approved test system means a test system cleared or approved by the FDA through the premarket notification (510(k)) or premarket approval (PMA) process for in-vitro diagnostic use. Unless otherwise stated, this includes test systems exempt from FDA premarket clearance or approval. HHS means the Department of Health and Human Services, or its designee. Immediate jeopardy means a situation in which immediate corrective action is necessary because the laboratory's noncompliance with one or more condition level requirements has already caused, is causing, or is likely to cause, at any time, serious injury or harm, or death, to individuals served by the laboratory or to the health or safety of the general public. This term is synonymous with imminent and serious risk to human health and significant hazard to the public health. Intentional violation means knowing and willful noncompliance with any CLIA condition. Kit means all components of a test that are packaged together. Laboratory means a facility for the biological, microbiological, serological, chemical, immunohematological, hematological, biophysical, cytological, pathological, or other examination of materials derived from the human body for the purpose of providing information for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings. These examinations also include procedures to determine, measure, or otherwise describe the presence or absence of various substances or organisms in the body. Facilities only collecting or preparing specimens (or both) or only serving as a mailing service and not performing testing are not considered laboratories. Laboratory training or experience means that the training or experience must be obtained in a facility that meets the definition of a laboratory under this section and is not excepted under § 493.3(b). Midlevel practitioner means a nurse midwife, nurse practitioner, nurse anesthetist, clinical nurse specialist, or physician assistant licensed by the State within which the individual practices, if such licensing is required in the State in which the laboratory is located. Nonwaived test means any test system, assay, or examination that has not been found to meet the statutory criteria specified at section 353(d)(3) of the Public Health Service Act. Operator means the individual or group of individuals who oversee all facets of the operation of a laboratory and who bear primary responsibility for the safety and reliability of the results of all specimen testing performed in that laboratory. The term includes— (1) A director of the laboratory if he or she meets the stated criteria; and (2) The members of the board of directors and the officers of a laboratory that is a small corporation under subchapter S of the Internal Revenue Code. Owner means any person who owns any interest in a laboratory except for an interest in a laboratory whose stock and/or securities are publicly traded. (That is e.g., the purchase of shares of stock or securities on the New York Stock Exchange in a corporation owning a laboratory would not make a person an owner for the purpose of this regulation.) Party means a laboratory affected by any of the enforcement procedures set forth in this subpart, by CMS or the OIG, as appropriate. Peer group means a group of laboratories whose testing process utilizes similar instruments, methodologies, and/or reagent systems and is not to be assigned using the reagent lot number level. Performance characteristic means a property of a test that is used to describe its quality, e.g., accuracy, precision, analytical sensitivity, analytical specificity, reportable range, reference range, etc. Performance specification means a value or range of values for a performance characteristic, established or verified by the laboratory, that is used to describe the quality of patient test results. Physician means an individual with a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine degree who is licensed by the State to practice medicine, osteopathy, or podiatry within the State in which the laboratory is located. Principal sanction means the suspension, limitation, or revocation of any type of CLIA certificate or the cancellation of the laboratory's approval to receive Medicare payment for its services. Prospective laboratory means a laboratory that is operating under a registration certificate or is seeking any of the three other types of CLIA certificates. Rate of disparity means the percentage of sample validation inspections for a specific accreditation organization or State where CMS, the State survey agency or other CMS agent finds noncompliance with one or more condition level requirements but no comparable deficiencies were cited by the accreditation organization or the State, and it is reasonable to conclude that the deficiencies were present at the time of the most recent accreditation organization or State licensure inspection. Example: Assume the State survey agency, CMS or other CMS agent performs 200 sample validation inspections for laboratories accredited by a single accreditation organization or licensed in an exempt State during a validation review period and finds that 60 of the 200 laboratories had one or more condition level requirements out of compliance. CMS reviews the validation and accreditation organization's or State's inspections of the validated laboratories and determines that the State or accreditation organization found comparable deficiencies in 22 of the 60 laboratories and it is reasonable to conclude that deficiencies were present in the remaining 38 laboratories at the time of the accreditation organization's or State's inspection. Thirty-eight divided by 200 equals a 19 percent rate of disparity. Referee laboratory means a laboratory currently in compliance with applicable CLIA requirements, that has had a record of satisfactory proficiency testing performance for all testing events for at least one year for a specific test, analyte, subspecialty, or specialty and has been designated by an HHS approved proficiency testing program as a referee laboratory for analyzing proficiency testing specimens for the purpose of determining the correct response for the specimens in a testing event for that specific test, analyte, subspecialty, or specialty. Reference range means the range of test values expected for a designated population of individuals, e.g., 95 percent of individuals that are presumed to be healthy (or normal). Reflex testing means confirmatory or additional laboratory testing that is automatically requested by a laboratory under its standard operating procedures for patient specimens when the laboratory's findings indicate test results that are abnormal, are outside a predetermined range, or meet other pre-established criteria for additional testing. Repeat proficiency testing referral means a second instance in which a proficiency testing sample, or a portion of a sample, is referred, for any reason, to another laboratory for analysis prior to the laboratory's proficiency testing program event cut-off date within the period of time encompassing the two prior survey cycles (including initial certification, recertification, or the equivalent for laboratories surveyed by an approved accreditation organization). Replacement certificate means an active CLIA certificate that is reissued with no changes made. Reportable range means the span of test result values over which the laboratory can establish or verify the accuracy of the instrument or test system measurement response. Revised certificate means an active CLIA certificate that is reissued with changes to one or more fields displayed on the certificate, such as the laboratory's name, address, laboratory director, or approved specialties/subspecialties. For purposes of this part, revised certificates do not include the issuance, renewal, change in certificate type, or reinstatement of a terminated certificate with a gap in service. Sample in proficiency testing means the material contained in a vial, on a slide, or other unit that contains material to be tested by proficiency testing program participants. When possible, samples are of human origin. State includes, for purposes of this part, each of the 50 States, the District of Columbia, the Commonwealth of Puerto Rico, the Virgin Islands and a political subdivision of a State where the State, acting pursuant to State law, has expressly delegated powers to the political subdivision sufficient to authorize the political subdivision to act for the State in enforcing requirements equal to or more stringent than CLIA requirements. State licensure means the issuance of a license to, or the approval of, a laboratory by a State laboratory program as meeting standards for licensing or approval established under State law. State licensure program means a State laboratory licensure or approval program. State survey agency means the State health agency or other appropriate State or local agency that has an agreement under section 1864 of the Social Security Act and is used by CMS to perform surveys and inspections. Substantial allegation of noncompliance means a complaint from any of a variety of sources (including complaints submitted in person, by telephone, through written correspondence, or in newspaper or magazine articles) that, if substantiated, would have an impact on the health and safety of the general public or of individuals served by a laboratory and raises doubts as to a laboratory's compliance with any condition level requirement. Target value for quantitative tests means: (1) If the peer group consists of 10 participants or greater: (i) The mean of all participant responses after removal of outliers (that is, those responses greater than three standard deviations from the original mean, as applicable); (ii) The mean established by a definitive method or reference methods; or (iii) If a definitive method or reference methods are not available, the mean of a peer group; or (2) If the peer group consists of fewer than 10 participants, the mean of all participant responses after removal of outliers (as defined in paragraph (1) of this definition) unless acceptable scientific reasons are available to indicate that such an evaluation is not appropriate. Test system means the instructions and all of the instrumentation, equipment, reagents, and supplies needed to perform an assay or examination and generate test results. Unsatisfactory proficiency testing performance means failure to attain the minimum satisfactory score for an analyte, test, subspecialty, or specialty for a testing event. Unsuccessful participation in proficiency testing means any of the following: (1) Unsatisfactory performance for the same analyte in two consecutive or two out of three testing events. (2) Repeated unsatisfactory overall testing event scores for two consecutive or two out of three testing events for the same specialty or subspecialty. (3) An unsatisfactory testing event score for those subspecialties not graded by analyte (that is, bacteriology, mycobacteriology, virology, parasitology, mycology, blood compatibility, immunohematology, or syphilis serology) for the same subspecialty for two consecutive or two out of three testing events. (4) Failure of a laboratory performing gynecologic cytology to meet the standard at § 493.855. Unsuccessful proficiency testing performance means a failure to attain the minimum satisfactory score for an analyte, test, subspecialty, or specialty for two consecutive or two of three consecutive testing events. Validation review period means the one year time period during which CMS conducts validation inspections and evaluates the results of the most recent surveys performed by an accreditation organization or State laboratory program. Waived test means a test system, assay, or examination that HHS has determined meets the CLIA statutory criteria as specified for waiver under section 353(d)(3) of the Public Health Service Act. [57 FR 7139, Feb. 28, 1992, as amended at 57 FR 7236, Feb. 28, 1992; 57 FR 34013, July 31, 1992; 57 FR 35761, Aug. 11, 1992; 58 FR 5220, Jan. 19, 1993; 58 FR 48323, Sept. 15, 1993; 60 FR 20043, Apr. 24, 1995; 63 FR 26732, May 14, 1998; 68 FR 3702, Jan. 24, 2003; 68 FR 50723, Aug. 22, 2003; 79 FR 25480, May 2, 2014; 79 FR 27157, May 12, 2014; 85 FR 54873, Sept. 2, 2020; 87 FR 41232, July 11, 2022; 88 FR 90035, Dec. 28, 2023; 88 FR 90035, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.15 Laboratories performing waived tests

§ 493.15 Laboratories performing waived tests. (a) Requirement. Tests for certificate of waiver must meet the descriptive criteria specified in paragraph (b) of this section. (b) Criteria. Test systems are simple laboratory examinations and procedures which— (1) Are cleared by FDA for home use; (2) Employ methodologies that are so simple and accurate as to render the likelihood of erroneous results negligible; or (3) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of waiver tests. A laboratory may qualify for a certificate of waiver under section 353 of the PHS Act if it restricts the tests that it performs to one or more of the following tests or examinations (or additional tests added to this list as provided under paragraph (d) of this section) and no others: (1) Dipstick or Tablet Reagent Urinalysis (non-automated) for the following: (i) Bilirubin; (ii) Glucose; (iii) Hemoglobin; (iv) Ketone; (v) Leukocytes; (vi) Nitrite; (vii) pH; (viii) Protein; (ix) Specific gravity; and (x) Urobilinogen. (2) Fecal occult blood-non-automated; (3) Ovulation tests—visual color comparison tests for human luteinizing hormone; (4) Urine pregnancy tests—visual color comparison tests; (5) Erythrocyte sedimentation rate—non-automated; (6) Hemoglobin—copper sulfate—non-automated; (7) Blood glucose by glucose monitoring devices cleared by the FDA specifically for home use; (8) Spun microhematocrit; and (9) Hemoglobin by single analyte instruments with self-contained or component features to perform specimen/reagent interaction, providing direct measurement and readout. (d) Revisions to criteria for test categorization and the list of waived tests. HHS will determine whether a laboratory test meets the criteria listed under paragraph (b) of this section for a waived test. Revisions to the list of waived tests approved by HHS will be published in the Federal Register in a notice with opportunity for comment. (e) Laboratories eligible for a certificate of waiver must— (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. [57 FR 7139, Feb. 28, 1992, as amended at 58 FR 5221, Jan. 19, 1993; 82 FR 48773, Oct. 20, 2017]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

FAQ

Common questions

Can a nurse practitioner be a lab director?

An NP can direct a PPM lab if the state lets NPs practice independently. NPs are not a named category for moderate or high complexity; an NP would need to meet a degree-based pathway (for example the bachelor's pathway with 2 years of nonwaived experience, 2 years of supervisory experience and 20 CE hours).

Do I need 20 CE hours if I am a board-certified pathologist?

No. The pathologist pathway for both moderate and high complexity has no separate CE requirement.

Can a PhD be a high complexity lab director?

Yes, if the doctorate qualifies, the person is certified by an HHS-approved board, has the required 2 years of experience, and has 20 CE hours.

Does a podiatrist qualify?

A licensed DPM can qualify under the physician pathway for moderate (1 year) or high (2 years) complexity, with 20 CE hours.

Get a laboratory director

Tell us about your lab

Send the form and a Sound Lab Consultants team member replies within one business day with director options for your state, test menu and complexity.

Request a lab director

No obligation. Your details go only to Sound Lab Consultants.

Prefer to talk now? Call (602) 874-1311.

✓

Thank you. We have your request.

A Sound Lab Consultants team member will reply within one business day. To skip the wait, book a call now

Need a qualified laboratory director?

Sound Lab Consultants provides CLIA laboratory directors for waived, PPM, moderate and high complexity labs in all 50 states.